Investigating effects of freezing conditions on micro-duct air-blown cables By Yunfang Ruan, Zhuang Xiong, Xiaoli Liu and Wenjing Ye, State Key Laboratory of Optical Fibre and Cable Manufacture Technology, Yangtze Optical Fibre and Cable Joint Stock Co Ltd, and Huawei Technologies Co Ltd, Shenzhen, Guangdong, China
Abstract In some cold areas, freezing conditions are a potential threat to micro-duct air-blown cables. In order to study the effects of freezing conditions on the transmission performance of optical fibres in micro-duct air-blown cables, two different experiments were designed and carried out in this paper. The test results reveal that both freezing in micro-ducts and that around end caps have insignificant influence on the transmission performance of the fibres and no visual physical damage to the cable has been detected after the experiments. 1 Introduction With the development of FTTx network construction, micro-duct air-blown cables are more frequently used due to the lack of duct resources, even in some cold regions. In this case, the water permeated into the micro-duct will be frozen under such low temperatures. Some concern such as the cable performance deterioration will discourage the wide application of micro-duct air-blown cables all over the world. In order to study the effects of freezing conditions on the transmission performance of optical fibres, freezing tests were designed to simulate the cold climate with the aid of a temperature cycling chamber. During the tests, the attenuation change of the fibres was monitored, and the appearance of the cable was checked. The test procedures are described in detail and the test results are carefully analysed. 2 Freezing test conditions Two experiments were designed to simulate the conditions of water frozen in the micro-duct and around the end caps
Stranded loose tube structure with G.652D fibres
Cable type
Fibre count Cable OD
96
6.1mm HDPE
Micro-duct type
OD/ID of micro-duct
10/8mm
TCT cycles
2
❍ ❍ Table 1 : Common test conditions
❍ ❍ Figure 1 : Micro-duct with cable soaked in water
respectively with the aid of a temperature cycling chamber. The common test conditions in two experiments are shown in Table 1 . 3 Test for water frozen in micro-duct This experiment is designed to study the impact of freezing conditions on fibre attenuation while water is frozen in the micro-duct, and performed in accordance with IEC60794-1-22 Method F15: cable external freezing test.
73
www.read-wca.com
Wire & Cable ASIA – March/April 2017
Made with FlippingBook